Preamble

The results of the simulations are influenced by the direction of the material coordinates. Often, a one-time rotation is sufficient. To facilitate this rotation, we have included several lists of parameters and variables that can be used by users. It is important to note that this rotation will be around one of the three spatial coordinates.

Definitions

Note that the list Reduced Coefficients doesn’t do any rotation. It just reduces the prefix root.material.StressCharge., so that the other lists will not be too cumbersome.

Global Parameters - Reduced Coefficients

Global Variables - Rotate around x-axis

Global Variables - Rotate around y-axis

Global Variables - Rotate around z-axis

Their corresponding “.txt” files are here:

Reduced Coefficients.txt

Rotate around x-axis.txt

Rotate around y-axis.txt

Rotate around z-axis.txt

How to use

The list Reduced Coefficients is always necessary. Please do not disable it after importing it.

Select Materials

Right-click Comp1Materials, then use Add Material from Library and select what you need.

Please remember to select Domains for each material.

The default Relative permeability in this model is 1 and the default Electrical conductivity is 0.